1
|
QIAamp DNA Blood Mini Kit (Qiagen, Hilden, Germany)
|
DNA extraction from serum samples
|
32927082
|
View Related Publication
|
|
2
|
TaqMan system (Applied Biosystems 7500 Real-Time PCR System, Applied Biosystems, USA)
|
Real-time PCR for molecular detection and quantification of B19V
|
|
3
|
Synthetic standard curve of the B19V NS1 region (IDT, USA)
|
Absolute quantification in real-time PCR
|
|
4
|
Primers for the NS1 region (nt 1905F and 1987R) and a single labelled 50 FAM probe (nt 1925–1948, GenBank: NC_000883.2)
|
Real-time PCR amplification
|
|
5
|
ELISA kits (VirionSerion, Germany)
|
Detection of anti-B19V IgM and IgG antibodies
|
|
6
|
Primer pairs VP1/VP1R (nt 3502–3883, GenBank: NC_000883.2) and VP2/VP2R (nt 3541–3867, GenBank: NC_000883.2)
|
Nested PCR for B19V genotyping
|
|
7
|
QIAquick gel extraction (Qiagen, Germany)
|
Purification of nested PCR products
|
|
8
|
BigDye terminator v. 1.1 cycle sequencing kit (Applied Biosystems, USA)
|
Sequencing of nested PCR products
|
|
9
|
HBsAg, anti-HBc, anti-HBs, and anti-HCV ELISA kits (Euroimmun, Germany)
|
Testing for hepatitis B and C markers
|